Runway 16/34 Rehabilitation Project – Dublin Airport
Project completed: 27/8/19
Mainline Power completed the following as a part of the project:
- The project is for the structural overlay/rehabilitation of the Runway 16/34.
- The project includes AGL (Aerodrome Ground Lighting) infrastructure to future proof for reducing the runway width to 45m and for taxiing in low visibility conditions and addressing minor non- compliances on Taxiway E1
- As part of this contract existing AGL systems are required to be temporarily decommissioned with the areas of the structural overlay/rehabilitation works and reinstated as required including but not limited to taxiway centreline, taxiway edge, stopbars, runway end, Threshold, Approach, Supplementary Approach, Stopway fittings, Touch Down Zone fittings.
- Mainline Surveyed and identified existing and new primary circuit routes to ensure ducts were usable.
- Protection provided to the existing secondary cabling of the disconnected fittings
- Made safe, disconnected and salvaged existing fittings.
- Secondary leads were placed into the AGL inner core and protected. Fittings were retained for future re-installation.
- Disconnected and stripped-out/salvaged the follow fittings:
- Elevated Threshold/Rwy End
- Inset Threshold/Rwy End
- Runway Identification Lighting System (RTILS)
- Touch down zone fittings (TDZ)
- Runway Centerline
- Stopbar
- Taxiway Centerline
- Taxiway Edge
- Approach fittings
- Supplementary approach
- Installed new 12” shallow bases including supply of mortar and grout.
- Installed new 8” shallow bases including supply of mortar and grout.
- Installed 12” blanking plates on shallow bases.
- Installed 8” blanking plates on shallow bases.
- Installed temporary elevated Threshold/RWY end fittings including surface mounted baseplate.
- Installed elevated Threshold/RWY end fittings in final position following completion of works in area.
- Supplied, made up with flying secondary leads and installation of new secondary cables (and earth cable) via existing/new ducts or saw-cuts from new shallow base to the edge of the runway in temp pits or existing manhole and connected to isolating transformer.
- Labeled all secondary cables, isolating transformers and manholes as directed on site.
- Reconfiguration of Taxiway E1 centreline lighting primary and secondary cables and transformers including installation of new bi-directional taxiway centreline fittings
- Recalibrate the existing CCR’s associated with Taxiway “E1”
- Test and commission reinstated AGL systems in conjunction with a DAA representative